BESS

ES3344-2 BESS Container

Technical Parameters
AC Side (Grid Tied Scenario)
AC Output Power 1000kW
Max. AC Current 921A
Nominal AC Voltage / Range 690V (-20% ~ 15%)
Nominal Grid Frequency/Range 50Hz / 47Hz ~ 52Hz 60Hz / 57Hz ~ 62Hz
Harmonic(THD) <3%% (at Nominal Power)
Power Factor at Nominal Power/Adjustable -1 ~ 1
Cooling Concept of PCS Chamber Air Cooling
Seamless Switching from Grid to BESS In Case of Power Outage Optional
AC Side (Microgrid Scenairo)
Nominal AC Voltage 690V
Harmonic (THD) < 1%% (Resistance Load)
Nominal Frequency/Range 50Hz/45Hz ~ 55Hz 60Hz/55Hz ~ 65Hz
Max. AC Power 1100kW
Batteries
Nominal Battery Voltage 1331.2VDC
Battery Type LiFePO4 3.2V/314Ah
Battery Pack Configuration 1P104S/104.4992kWh
Battery System Configuration 8P416S
Capacity 3343.9744kWh
Battery Voltage Range 1164.8-1497.6VDC
Max Charging/Discharging Current 1256A
Battery Disconnect Integrated
Cooling concept of battery chamber Liquid Cooling
General Parameters
Dimension W*D*H 6058*2438*2896mm
Charge/Discharge Rate 0.5C
Depth of Discharge 95%
Life Cycle 6000
Degree of Protection IP54
System Efficiency ≥91%
Fire Protection System Aerosol
Allowed Ambient Temperature -30 ~ 60˚C (>45˚C Derating)
Allowed Relative Humidity 0 ~ 95%
Working Altitude <2000m
Enclosure Corrosion Resistance Level C4/C5
Weight ~32000kg
SPD DC TYPE Ⅱ/AC TYPE Ⅱ
Lifting Options Fork/Crane
Scalability Yes, Units Can Be Connected In Parallel
Monitoring
Display 7 Inches Touchscreen
Communication Ethernet
Communication Protocols MODBUS-RTU/MODBUS-TCP
Remote Control System Renepoly Cloud
Certifications
Battery Cell CE, RoHS, UN38.3, MSDS, UL, ESG
Battery Pack CE, UN38.3
Battery Rack CE, UN38.3
Power Conversion System CE(IEC61000 IEC62619 IEC62109)EN50549-1, EN50549-2, IEC61727&62116, NRS097, VDE4105, VDE4110, VDE4120, C10/11, G99, PN50549, EIFS2018:02, CEI021/16, NTS632:2019, MEA, PEA, UNE, RD EN 50549 with deviations of grid protection settings for Greece&Sweden&Denmark(DK&DK2)&Netherland&Czech&Hungary&Romania